Tools

Siemens Global WebsiteSiemens Global Website

Energy Efficiency

 

 

Financing

How can energy-efficient solutions be financed intelligently?

With financing solutions from Siemens Financial Services, modernizations, investments in energy efficiency and in equipment can be realized.

Siemens Financial Services
Evaluate Energy-Saving Potential


Power Distribution

How can my energy distribution contribute to energy management – and how can partial plant failures be detected in time?

The 7KM PAC Monitoring Devices send the switch disconnector current values and switching states to the energy management software powermanager in the administrative building in order to monitor the supply and visualize the energy consumption.

SENTRON powermanager
SENTRON Measuring, Switching and Protection Devices

How do the monitoring and documentation of the building floor distribution contribute to energy management?

The Monitoring Device 7KM PAC4200 in the infeed panel of the main distribution board and switch disconnectors, combined with Monitoring Device 7KM PAC3100 in the lower-level installation distribution boards, supply the energy management software powermanager with measurement data for visualizing energy consumption and thus for tracking down any potential savings.

SENTRON powermanager
SENTRON Measuring, Switching and Protection Devices

How can the energy costs of different units be allocated to cost centers?

The SENTRON 7KT PAC1500, 7KM PAC4200, 7KM PAC3100 measuring devices and the powermanager software for energy management enable the allocation of energy costs on a "user pays" basis.

SENTRON powermanager
SENTRON Measuring, Switching and Protection Devices

How can the energy costs of different units be allocated to cost centers and visualized on a PC with standard office applications?

The SENTRON Monitoring Devices 7KT PAC3000 and 7KT PAC1500 supply the recorded measured data via RS485 interface to the LAN coupler where it is saved in the form of a csv file.

Energy Management for Industry
SENTRON Measuring, Switching and Protection Devices


Lighting Systems

How can light levels in office buildings be adjusted according to the available daylight?

GAMMA Building Control enables the automatic constant light level control with brightness sensor and switching/dimming actuators together with OSRAM components realizing energy savings dependent on the available daylight.

GAMMA Building Control
OSRAM Professionals

How can light levels in office buildings be adjusted according to occupancy and available daylight?

GAMMA Building Control enables the automatic constant light level control with presence detector realizing energy savings depending on the available daylight and the presence of persons in the area.

GAMMA Building Control
OSRAM Professionals

How can energy be saved by replacing lamps and using electronic control gears in office buildings?

The use of electronic control gears OSRAM QT FIT 8 and of OSRAM T8 LUMILUX®/SKYWHITE lamps instead of conventional control gears results in energy savings of up to 20%.

OSRAM Light Consultant

How can energy be saved on parking lots with lighting control dependent on time and brightness?

SENTRON Protection and switching devices enable the automatic time and brightness-dependent lighting control with time switch, dusk switch and OSRAM electronic control gear.

SENTRON Protection and Switching Devices
OSRAM Professionals

How can you save energy in stairwells with a time-dependent light controller?

Automatic, time-dependent lighting control via stairwell time switches with SENTRON protection and switching devices can contribute to savings of up to 20 % of the energy costs.

SENTRON Protection and Switching Devices
OSRAM Professionals

How can energy be saved with time-dependent light control?

GAMMA Building Control enable automatic light level control with time switch and OSRAM components realizing savings of up to 20% of energy costs depending on day's and week's programs as well as sunrise and sunset times.

GAMMA Building Control
DELTA Switches and Sockets
OSRAM Professionals

How can I manually adapt the lighting intensity in the office?

With GAMMA Building Control and OSRAM lighting components - concretely using electronic control gears instead of conventional control gears, the lighting level can be adapted manually with infinite variations to match the actual demand.

GAMMA Building Control
OSRAM

How can the lighting level in an office building be controlled depending on presence and daylight?

Presence-dependent and daylight-dependent lighting controls within the scope of LMS can be adapted flexibly to the relevant requirements, e.g. DALI MULTIeco control unit with light and presence sensor, OSRAM Qti DALI electronic control gears and OSRAM T5 LUMILUX® luminaire.

DELTA Switches and Sockets
OSRAM Professionals

How can the light intensity in residential buildings be adjusted manually?

SENTRON protection and switching devices with DELTA dimmers for incandescent and high-voltage halogen lamps enable the full adjustment of the lighting intensity to the desired atmosphere in the room.

DELTA Switches and Sockets
SENTRON Protection and Switching Devices


Room Automation

How can you make significant energy savings in the office with a simple expansion to the heating control system?

GAMMA Building Control enables automatic control of heating valves with room temperature regulator and thermal drive actuator.

GAMMA Building Control

How can offices be ventilated efficiently?

The ventilation control with GAMMA Building Control and the LOGO! logic module with sensor technology to control the fan motor results in energy savings of up to 10% in the area of passive cooling.

GAMMA Building Control
SYMARO Room Air Quality Sensors
LOGO! Logic Module

How can water heating in buildings be managed in an energy-efficient manner?

SENTRON protection and switching devices enable an automatic time-dependent control of electric storage water heaters with digital time switch reaching energy savings of up to 20 %.

SENTRON Protection and Switching Devices
DELTA Switches and Sockets

How can energy be saved with a simple automatic blind control system?

The automatic blind control with dual sensor and blind actuator from GAMMA Building Control can lead to energy savings of up to 30%.

GAMMA Building Control
DELTA Switches and Sockets

How can heating energy use be optimized and comfort increased in a domestic dwelling?

The QAW912 room unit can control up to 6 radiator control actuators without cabling. This saves up to 30% of energy.

Home Automation System Synco living


Energy Efficient Products and Tools

How can power supplies be used to save energy and space?

With SITOP compact energy savings of up to 35% can be realized.

SITOP Power Supply

How can the energy-saving potential of new drive systems be calculated?

SinaSave energy efficiency software calculates the possible cost saving potential in your specific drive applications.

Software SinaSave
Energy-efficient Production


Electromobility

How can a charging station for electric vehicles be set up simply and safely?

The right low-voltage energy distribution compoents must be used to suit the prevailing charging power, environmental conditions and location. The products meet the requirements regarding short-circuit protection, climatic environmental conditions, system configuration and safety engineering.

Low-Voltage Power Distribution
Industrial Controls - SIRIUS


Photovoltaic Systems

Which components are required for safe, efficient construction and operation of commercial PV plants?

Standard-compliant, field-proven and high-quality devices for protection, switching, measuring, and monitoring guarantee a safe construction and operation of a PV plant.

Low voltage Photovoltaic

How can PV strings/generators be safely disconnected during maintenance and inspection or in the event of fire?

The DC safety disconnector 5TE2 515-1 can be integrated into existing string boxes or generator boxes and enables selective shutdown of individual PV strings/generators.

Low voltage Photovoltaic

How do I achieve safe and cost-effective construction and operation of PV power plants?

A comprehensive, coordinated portfolio of protection components ensures standard-compliant construction and operation of photovoltaic power plants.

Low voltage Photovoltaic